HydroAir Genesis Air Blower - G50-2AH-S

500W - Heated - Pneumatic - On/Off Only

HydroAir Genesis Air Blower - G50-2AH-S

500W - Heated - Pneumatic - On/Off Only
£209.99
Quick Find Code: 3519
Quantity
In stock 2 in stock
In stock Same day dispatch on orders before 14:30
Delivery
Returns
Loyalty Points
  • FREE Standard UK Mainland delivery (Min order £35)
  • Express UK Mainland Delivery £8.40 (next working day)
Postcode restrictions apply. See full delivery details here
We want you to be happy with your purchase. If you're not then please return the products to us within 30 days
See our returns policy

You can now collect Loyalty Points for every order you place online with us.

  • You get 5 points for every pound you spend.
  • 100 points = £1.00 to use against future orders.
  • Use your Loyalty Points to get a discount on any future orders over £10.
Share this product
Share this product on Twitter Share this product on Facebook Share this product on LinkedIn Share this product on Google Plus Share this product on Youtube
(0 reviews)
Product Description
Downloads & Articles
More Info
Product Description

HydroAir Genesis Air Blower - G50-2AH-S 500W - Heated - Pneumatic

The HydroAir Genesis range of blowers are easily identified by their distinctive blue casing. They are used by many hot tub manufactures but will more commonly be found as the blower of choice in many whirlpool baths out there.
The Genesis range all feature rotatable outlets making installation easy and a threaded 1.50"BSP x 32mm union is included.
A host of options and features are available throughout the range. See the specifications below.

The G50-2AH-S comes fitted with a pneumatic control box which allows, the blower to be operated by the push of an air button.

Top Tips:

Blowers with integral heaters, heat the air flow and don't cool the water down as fast or feel cold on your body, giving a far more enjoyable bathing experience.

If you are planning to upgrade to a heated blower, it is recommend to check that your plumbing can cope with the additional heat generated by a heated blower. Always refer to the manufactures speifacations and guidelines.

Useful Info:

  • 500W version - Used mainly in whirlpool baths and small hot tubs.
  • 700W version - Used mainly in whirlpool baths and small to medium sized hot tubs.
  • 900W version - Used mainly in hot tubs, some large whirlpool baths. 
  • 1200W version - Used mainly in swimming pools but can also be found in large hot tubs or spas.

 

More Info

Genesis Blower Range Overview

 

NN =
Standard blower for electronic control/touch pad
AN =
Pneumatic air switch / Pneumatic on/off blower
HN=
Heater,Standard blower for electronic control/touch pad with built-in heating element to reduce cold air in upstart.
AH=
Pneumatic air switch & heater, Pneumatic on/off blower with built-in heating to reduce cold air in upstart.
VN=
Variable speed, Standard blower including variable massage mode and automatic dry-out when using special touch pad UK01658A connected directly to blower. No seperate control panel needed. See functional description under "VH".
VH=
Variable speed & heater, Standard blower including variable massage mode and automatic dry-out when using
special touch pad UK01658A connected directly to blower. No seperate control panel needed. The blower has built-in heating lement to reduce cold air in upstart. 

Functional description for preset programme:
- Press the on/off button = high speed.
- Press the +/- button = in-/decrease blower speed.
- Press the ~ button = massage mode "pulsating effect"

Automatic stop: blower stops 30 min. after the user has operated one of the buttons for the last time. Drying cycle: 30 min. after manual or auto switch off, the blower starts up at high speed for 2 secs. It then drops to low speed and increases gradually to high speed within 30 sec. The blower will then continue running 4½ min. at high speed to drain remaining water from the pipes.
VNT=
Electronic 3-speed blower. With variable massage mode and automatic dry-out of air system. To be used with
one on/off touch or LED button. See functional descriptions under "VHT"
 VHT
Electronic 3-speed blower with built-in heating element to reduce cold air in upstart. With variable massage
mode and automatic dry-out of air system. To be used with one on/off touch or LED button.
Functional description for "VNT" and "VHT":
1. First press = high speed
2. Second press = medium speed
3. Third press = low speed
4. Fourth press = massage mode "pulsating effect"
5. Fifth press = off
Automatic safety stop after 30 minutes
ANT=
Pneumatic air switch & 3-speed Pneumatic on/off blower including massage mode, automatic dry-out when using standard pneumatic air button. See functional description under "AHT".
AHT=
Pneumatic air switch, 3-speed & heater, Pneumatic on/off blower including massage mode, automatic dry-out when using standard pneumatic air switch. With built-in heating element to reduce cold air in upstart.
Functional description for preset programme:
1. Press the pneumatic button = high speed.
2. Press the pneumatic button = medium speed.
3. Press the pneumatic button = low speed.
4. Press the pneumatic button = massage mode "pulsating effect".
5. Press the pneumatic button = off.

Automatic stop: blower stops 30 min. after the user has operated one of the buttons for the
last time Drying cycle: 30 min. after manual or auto switch off, the blower starts up at high
speed for 2 secs. It then drops to low speed and increases gradually to high speed within
30 sec. The blower will then continue running 4½ min. at high speed to drain remaining
water from the pipes.
Customer Reviews
Questions & Answers
Customer Reviews

There are currently no reviews for this product.

Be the first the write a review.

Write a review
Your Name*:
Your Comments*:
Your Rating:  *  *  *  *  *
* = required fields
Questions & Answers

There are currently no questions for this product.

Ask us a question